Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Life Sci Space Res (Amst) ; 39: 43-51, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37945088

RESUMO

The data from two Bulgarian-German instruments with the basic name "Radiation Risk Radiometer-Dosimeter" (R3D) are discussed. The R3DR instrument worked inside the ESA EXPOSE-R facility (2009-2010), while R3DR2 worked inside the ESA EXPOSE-R2 facility (2014-2016). Both were outside the Russian Zvezda module on the International Space Station (ISS). The data from both instruments were used for calculation of the neutron dose equivalent rate. Similar data, obtained by the Russian "BTNNEUTRON" instrument on the ISS are used to benchmark the R3DR/R2 neutron dose equivalent rate. The analisys reveals that the "BTNNEUTRON" and R3DR/R2 values are comparable both in the equatorial and in the South Atlantic Anomaly (SAA) regions. The R3DR/R2 values are smaller than the "BTNNEUTRON" values in the high latitude regions. The comparison with the Monte Carlo simulations of the secondary galactic cosmic rays (GCR) neutron ambient dose equivalent rates (El-Jaby and Richardson, 2015, 2016) also shows a good coincidence with the R3DR/R2 spectrometer data obtained in the equatorial and high latitude regions.


Assuntos
Radiação Cósmica , Monitoramento de Radiação , Voo Espacial , Astronave , Doses de Radiação , Radiometria , Nêutrons
2.
Life Sci Space Res (Amst) ; 34: 30-36, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35940687

RESUMO

Calculation of radiation protection quantities in tissue equivalent material from measurements using semiconductor detectors requires correction factors for conversion of the measured values in the semiconductor material to the tissue equivalent material. This approach has been used many times in aircraft and for space dosimetry. In this paper, we present the results of Monte Carlo simulations which reveal the need to take into account both the radiation field and the detector material when performing the conversion of measured values to radiation protection quantities. It is shown that for low Z target material, most of the dose equivalent at aviation altitudes comes from neutrons originating from nuclear reactions, while in high Z targets most of the dose equivalent comes from photons, originating from electromagnetic reactions.


Assuntos
Nêutrons , Radiometria , Atmosfera , Método de Monte Carlo , Fótons , Doses de Radiação , Radiometria/métodos , Semicondutores
3.
Appl Radiat Isot ; 150: 19-24, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31108335

RESUMO

[13N]Ammonia is commonly produced using 16O(p, α)13N reaction but one of the limiting factor of this reaction is the relatively small nuclear cross-section at proton energies of <10 MeV. An alternative production method using 13C(p, n)13N reaction, which has a higher nuclear cross-section at low proton energies, is more suitable for a preclinical PET imaging facility equipped with a <10 MeV cyclotron. Here, we report a novel method to produce [13N]ammonia from [13C]methanol for preclinical use on a 7.5 MeV cyclotron. A tantalum solution target (80 µl) consisting of a havar window supplied by the cyclotron manufacturer for the production of [18F]fluoride was used without any modifications. The final bombardment parameters were optimized as follow: [13C]methanol concentration in target solution - 10%, bombardment time - 8 min, and beam current - 2.2 µA. These parameters provided doses of [13N]ammonia which were sufficient to conduct preclinical PET imaging studies in a mouse model of myocardial infarction. Under optimized conditions, the operational lifetime of the target was approximately 150 µAmin. Radionuclide identity of the product as 13N was confirmed by measuring the decay half-life and its radionuclide purity was confirmed by γ-ray spectroscopic analysis. Gas chromatography revealed that the final [13N]ammonia dose was not distinguishable from water, showing no traces of methanol. As expected, PET/CT imaging in healthy CD-1 mice indicated the accumulation of [13N]ammonia in myocardial tissue; mice with myocardial infarction created by left ascending coronary ligation showed clear perfusion deficit in affected tissue. This work demonstrates the proof-of-concept of using 13C(p, n)13N reaction to produce [13N]ammonia from [13C]methanol with a <10 MeV cyclotron, and its diagnostic application in imaging cardiac perfusion.


Assuntos
Amônia/farmacocinética , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/metabolismo , Compostos Radiofarmacêuticos/farmacocinética , Amônia/síntese química , Animais , Isótopos de Carbono/química , Ciclotrons , Modelos Animais de Doenças , Feminino , Metanol/química , Camundongos , Radioisótopos de Nitrogênio/química , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos/síntese química , Espectrometria gama
4.
Sci Rep ; 9(1): 3708, 2019 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-30842438

RESUMO

The linear energy transfer (LET) spectrum, absorbed dose and dose equivalent from secondary particles of LET∞H2O ≥15 keV/µm deposited within the plateau of the Bragg curve in primary particle-induced nuclear target fragmentation reactions in tissue during proton and heavy ion radiotherapy were measured using CR-39 plastic nuclear track detectors and analyzed by means of atomic force microscopy. It was found that secondary target fragments contributed 20% to dose equivalent for primary protons (157 MeV), 13% for primary helium ions (145 MeV/n) and 4% for primary carbon ions (383 MeV/n), respectively. Little research has been done on the contribution from these particles to primary given dose. The smaller contribution measured for energetic carbon ion beams compared to proton beams can be considered an advantage of carbon ion radiotherapy over proton radiotherapy.


Assuntos
Transferência Linear de Energia/fisiologia , Radiometria/métodos , Radioterapia com Íons Pesados/estatística & dados numéricos , Íons/metabolismo , Plásticos , Polietilenoglicóis , Prótons , Doses de Radiação
5.
Life Sci Space Res (Amst) ; 8: 38-51, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26948012

RESUMO

Most accelerator-based space radiation experiments have been performed with single ion beams at fixed energies. However, the space radiation environment consists of a wide variety of ion species with a continuous range of energies. Due to recent developments in beam switching technology implemented at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL), it is now possible to rapidly switch ion species and energies, allowing for the possibility to more realistically simulate the actual radiation environment found in space. The present paper discusses a variety of issues related to implementation of galactic cosmic ray (GCR) simulation at NSRL, especially for experiments in radiobiology. Advantages and disadvantages of different approaches to developing a GCR simulator are presented. In addition, issues common to both GCR simulation and single beam experiments are compared to issues unique to GCR simulation studies. A set of conclusions is presented as well as a discussion of the technical implementation of GCR simulation.


Assuntos
Radiação Cósmica , Laboratórios , Radiobiologia , Pesquisa , Estados Unidos , United States National Aeronautics and Space Administration
6.
Radiat Res ; 172(1): 21-9, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19580504

RESUMO

On a mission to Mars, astronauts will be exposed to a complex mix of radiation from galactic cosmic rays. We have demonstrated a loss of bone mass from exposure to types of radiation relevant to space flight at doses of 1 and 2 Gy. The effects of space radiation on skeletal muscle, however, have not been investigated. To evaluate the effect of simulated galactic cosmic radiation on muscle fiber area and bone volume, we examined mice from a study in which brains were exposed to collimated iron-ion radiation. The collimator transmitted a complex mix of charged secondary particles to bone and muscle tissue that represented a low-fidelity simulation of the space radiation environment. Measured radiation doses of uncollimated secondary particles were 0.47 Gy at the proximal humerus, 0.24-0.31 Gy at the midbelly of the triceps brachii, and 0.18 Gy at the proximal tibia. Compared to nonirradiated controls, the proximal humerus of irradiated mice had a lower trabecular bone volume fraction, lower trabecular thickness, greater cortical porosity, and lower polar moment of inertia. The tibia showed no differences in any bone parameter. The triceps brachii of irradiated mice had fewer small-diameter fibers and more fibers containing central nuclei. These results demonstrate a negative effect on the skeletal muscle and bone systems of simulated galactic cosmic rays at a dose and LET range relevant to a Mars exploration mission. The presence of evidence of muscle remodeling highlights the need for further study.


Assuntos
Densidade Óssea/efeitos da radiação , Radiação Cósmica/efeitos adversos , Úmero/efeitos da radiação , Fibras Musculares Esqueléticas/efeitos da radiação , Tíbia/efeitos da radiação , Animais , Peso Corporal/efeitos da radiação , Úmero/diagnóstico por imagem , Úmero/patologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Tamanho do Órgão , Doses de Radiação , Tíbia/diagnóstico por imagem , Tíbia/patologia , Microtomografia por Raio-X
7.
Radiat Res ; 171(2): 225-35, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19267549

RESUMO

Space radiation hazards are recognized as a key concern for human space flight. For long-term interplanetary missions, they constitute a potentially limiting factor since current protection limits for low-Earth orbit missions may be approached or even exceeded. In such a situation, an accurate risk assessment requires knowledge of equivalent doses in critical radiosensitive organs rather than only skin doses or ambient doses from area monitoring. To achieve this, the MATROSHKA experiment uses a human phantom torso equipped with dedicated detector systems. We measured for the first time the doses from the diverse components of ionizing space radiation at the surface and at different locations inside the phantom positioned outside the International Space Station, thereby simulating an extravehicular activity of an astronaut. The relationships between the skin and organ absorbed doses obtained in such an exposure show a steep gradient between the doses in the uppermost layer of the skin and the deep organs with a ratio close to 20. This decrease due to the body self-shielding and a concomitant increase of the radiation quality factor by 1.7 highlight the complexities of an adequate dosimetry of space radiation. The depth-dose distributions established by MATROSHKA serve as benchmarks for space radiation models and radiation transport calculations that are needed for mission planning.


Assuntos
Radiação Cósmica , Modelos Anatômicos , Voo Espacial , Humanos
8.
J Radiat Res ; 43 Suppl: S81-5, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12793736

RESUMO

The first InterComparison for Cosmic-ray with Heavy Ion Beams At NIRS (ICCHIBAN) project is an ongoing, international collaboration organized at the National Institute of Radiological Sciences (NIRS), Japan, for the purpose of characterizing and comparing at a controlled, ground-based heavy ion facility the radiation response of instruments used aboard piloted spacecraft for crew and area dosimetry. We present preliminary results from the first set of ICCHIBAN exposures made at HIMAC heavy ion accelerator in February 2002. The initial series of exposures (1st ICCHIBAN run) was designed to establish the response of active detectors to two well-characterized heavy ion beams; 400 MeV/nucleon 12C and 400 MeV/nucleon 56Fe. These beams are representative in charge and energy of two of the most significant heavy ion components present in the galactic cosmic radiation spectrum. The properties of the incident beam, including intensity, profile, charge and total energy, were characterized using several different detector systems, including silicon detectors, CR-39 plastic nuclear track detectors and plastic scintillation counters. Once the response of each detector to heavy ion beams of known composition has been measured, results from on-orbit measurements made by the different instruments can be more meaningfully compared. We conclude by discussing plans for future ICCHIBAN runs, including next 2nd ICCHIBAN run for passive detectors in early summer 2002.


Assuntos
Radiação Cósmica , Radiometria/instrumentação , Desenho de Equipamento , Íons Pesados , Japão , Astronave
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...